What This Means
This study compared how well computer software can measure body composition (muscle and fat amounts) from two different scans taken on the same day: a low-dose CT scan (part of a PET/CT) and a whole-body MRI. It included 42 people with multiple myeloma, a blood cancer. The software, based on a deep learning tool called TotalSegmentator, outlined skeletal muscle, fat under the skin, and fat in the abdomen on both scan types.
The two scan types agreed very closely overall (ICC above 0.95, meaning near-consistent ranking of patients). However, the MRI-based measurements gave systematically lower muscle volume (about 2.6 liters lower on average) and lower abdominal visceral fat (about 211 ml lower) than CT. Subcutaneous fat did not differ significantly. When looking at a single image slice rather than the whole body, fat measures still agreed well, but agreement for muscle was lower (ICC 0.87), with MRI giving a smaller muscle area on average.
This research suggests that CT and MRI can both be used for automated body composition analysis, but their numbers are not directly interchangeable. Combining data from the two scan types, or applying a single cutoff value regardless of scan type, may introduce errors unless these consistent differences are taken into account. The study was small and limited to multiple myeloma patients, so results may differ in other groups.