Cardiovascular

Bicuspid Aortic Valve With Preserved Ejection Fraction: One-Year Changes in Ventricular and Atrial Mechanics.

TL;DR

In selected patients with BAV who maintained preserved LVEF without valve or aortic surgery, LV GLS and LA reservoir strain decreased slightly over 1 year, though clinical significance requires validation with longitudinal controls and test-retest data.

Key Findings

At baseline, adults with bicuspid aortic valve and preserved EF had lower absolute LV global longitudinal strain than age- and sex-matched tricuspid aortic valve controls.

  • Absolute GLS was 17.8 ± 2.8% in BAV patients vs. 21.8 ± 1.0% in controls (p < 0.001).
  • The cohort included 82 BAV adults in sinus rhythm with LVEF ≥50% and 40 matched controls imaged once.
  • The study was a retrospective cohort.

At baseline, BAV patients also had lower left atrial reservoir strain (LASr) than controls.

  • LASr was 38.5 ± 5.2% in patients vs. 40.8 ± 3.4% in controls (p = 0.004).
  • Controls had tricuspid aortic valves and were age- and sex-matched.

Over about 1 year, mean LVEF and LV volumes did not change significantly in BAV patients, while absolute GLS decreased slightly.

  • Echocardiograms were 363 ± 15 days apart, without interim surgery.
  • Absolute GLS decreased by 0.8 percentage points (95% CI 0.5-1.1; Holm-adjusted p < 0.001).
  • Preserved LVEF (≥50%) was required at both examinations.

LA reservoir strain decreased over 1 year in BAV patients.

  • LASr fell by 2.4 points (95% CI 1.7-3.0; Holm-adjusted p < 0.001).
  • LASr and absolute GLS were the two primary outcomes.

Gradient-corrected global work index decreased over 1 year (exploratory outcome).

  • Decrease of 47 mmHg% (95% CI 27-68).
  • Myocardial work was corrected for the transaortic gradient in aortic stenosis and was an exploratory outcome.

A minority of patients showed a GLS decrease exceeding the intra-observer minimal detectable change.

  • GLS decrease exceeded the minimal detectable change in 22 patients (27%), versus an increase in 4 (5%).
  • Reader reproducibility was tested on stored images to derive the minimal detectable change.

The change in GLS was not significantly associated with valve lesion type or severity.

  • Lesion types included aortic stenosis and regurgitation; the gradient correction was applied for myocardial work in aortic stenosis.

The authors conclude the strain decreases were slight and that their clinical significance needs validation.

  • Findings apply to selected patients who maintained preserved LVEF without valve or aortic surgery.
  • Validation requires longitudinal controls and test-retest data; controls here were imaged only once.

What This Means

This study looked at adults born with a bicuspid aortic valve (a valve with two flaps instead of three) whose hearts still pumped normally by the usual measure, ejection fraction. Researchers compared heart ultrasound scans taken about one year apart in 82 such patients, and compared their first scans with those of 40 people with normal three-flap valves. Even though the pumping measure looked normal, the patients' heart muscle shortening (strain) and the filling function of the upper-left heart chamber were already lower than in the comparison group. Over one year, the usual pumping measure and heart chamber sizes did not change, but the strain measurements of both the main pumping chamber and the left atrium dropped slightly. The drop in heart-muscle strain was about 0.8 percentage points, and a measure of heart work efficiency also fell. About one in four patients had a decline larger than the measurement error of the method. The change did not clearly depend on the type or severity of the valve problem. This research suggests that strain measures might pick up subtle heart changes before the standard pumping measure changes. However, the changes were small, the study was retrospective and included only selected patients who did not need surgery, and the control group was scanned only once, so it is unclear what the drops mean for patients' health. The authors say more research with repeated scans in controls and repeat-measurement data is needed.

Have a question about this study?

Citation

Yalman H, Ayg&#xfc;n A, Temiz M, Raimoglou D, &#xc7;imci M. (2026). Bicuspid Aortic Valve With Preserved Ejection Fraction: One-Year Changes in Ventricular and Atrial Mechanics.. Echocardiography (Mount Kisco, N.Y.). https://doi.org/10.1111/echo.70665