Myocardial T1 Mapping at 3 T: A Comparison of MOLLI and ShMOLLI across Healthy Volunteers and Various Cardiovascular Pathologies.

TL;DR

In participants who underwent 3-T cardiac MRI with both MOLLI and ShMOLLI sequences, native T1 was higher with MOLLI than ShMOLLI, but ECV was consistent across sequences.

Key Findings

Reference native T1 values in healthy volunteers differed between MOLLI and ShMOLLI sequences at 3 T.

  • MOLLI native T1 reference value (adjusted mean ± SE): 1170 msec ± 9
  • ShMOLLI native T1 reference value: 1135 msec ± 10
  • ECV reference values were identical for both sequences: 24.8% ± 0.6
  • Study included healthy volunteers prospectively examined with both sequences in a single examination at 3 T

MOLLI yielded systematically higher native T1 values than ShMOLLI across all cardiovascular conditions and healthy volunteers.

  • Mean difference between MOLLI and ShMOLLI native T1: 46.0 msec ± 27.2
  • This difference was statistically significant across all groups (all P < .01)
  • The systematic bias was consistent regardless of the underlying cardiac condition
  • 13 cardiovascular pathology groups plus healthy volunteers and normal cardiac MRI participants were included

ECV values were consistent between MOLLI and ShMOLLI for most disease groups.

  • ECV did not differ significantly between sequences in 10 of 15 groups (P > .05)
  • Both sequences yielded ECV of 24.8% ± 0.6 in healthy volunteers
  • ECV showed strong intersequence correlation (Pearson r = 0.95; P < .001)
  • ECV agreement across sequences suggests it may be more robust to sequence-specific differences than native T1

Native T1 measurements showed strong intersequence correlation between MOLLI and ShMOLLI.

  • Pearson r = 0.93 for native T1 intersequence correlation (P < .001)
  • Pearson r = 0.95 for ECV intersequence correlation (P < .001)
  • Bland-Altman analysis was used to characterize agreement between sequences
  • Strong correlations support the technical validity and convertibility of measurements between the two sequences

After standardization to sequence-specific baselines, pathologic deviations from normal were comparable between MOLLI and ShMOLLI.

  • Cohen D differences between sequences were ≤0.5 in most disease groups after baseline standardization
  • This indicates that the diagnostic discrimination of pathology relative to normal reference values was similar for both sequences
  • Standardization approach used sequence-specific reference values to enable cross-sequence comparability
  • Findings applied across 13 different cardiovascular conditions

Women showed higher native T1 values than men in healthy volunteers for both sequences.

  • Sex difference in native T1 was statistically significant (all P ≤ .002)
  • This sex effect was observed with both MOLLI and ShMOLLI
  • 854 of 1237 total clinical participants were men
  • Findings underscore the importance of sex-specific reference values for T1 mapping

A supplementary swine study supported the technical validity of both MOLLI and ShMOLLI sequences.

  • Intersequence correlations in the swine study ranged from r = 0.87 to 0.90 (P < .001)
  • The animal study provided a controlled validation of the technical performance of both sequences
  • Results were consistent with findings from the human clinical study

The study enrolled 1237 clinical participants spanning healthy volunteers and 13 cardiovascular pathology groups.

  • Total sample: 1237 clinical participants (mean age ± SD: 51 years ± 14.8; 854 men)
  • Groups included healthy volunteers, participants with normal cardiac MRI findings, and 13 cardiovascular conditions
  • All participants underwent 3-T cardiac MRI with both MOLLI and ShMOLLI sequences during a single examination
  • This was a prospective study conducted at 3 T field strength
  • Statistical approaches included t tests, Pearson correlation, Bland-Altman analysis, and Cohen D standardization

What This Means

This research examined two commonly used heart MRI techniques — MOLLI and ShMOLLI — that measure a property of heart muscle tissue called T1 relaxation time, which can help detect various heart diseases. The study scanned 1,237 participants at 3 Tesla MRI strength, including healthy volunteers and people with 13 different heart conditions. It found that MOLLI consistently measured T1 values about 46 milliseconds higher than ShMOLLI across all groups, meaning the two techniques cannot be directly compared without accounting for this systematic difference. However, a related measurement called extracellular volume fraction (ECV), which reflects the amount of scar or fibrosis in heart tissue, was nearly identical between the two techniques for most conditions. This research suggests that when comparing T1 measurements between different hospitals or studies, it is critical to know which technique was used, since MOLLI and ShMOLLI give different absolute numbers even when measuring the same hearts. Despite this difference in raw T1 values, the ability of both techniques to distinguish diseased hearts from healthy ones was similar when measurements were compared against their own normal reference values. The study also found that women naturally have higher T1 values than men, highlighting the importance of using sex-specific reference ranges. Practically, this work provides a large set of reference values for both MOLLI and ShMOLLI at 3 Tesla MRI in a Chinese population across many heart conditions, filling an important gap since most prior reference data came from Western populations and often used only one technique. The findings support using ECV as a more sequence-independent measure and suggest that with proper baseline standardization, results from MOLLI and ShMOLLI can be meaningfully compared across clinical settings.

Have a question about this study?

Citation

Zhang H, Cui C, Zhou W, Zheng T, Yang W, Zhou D, et al.. (2026). Myocardial T1 Mapping at 3 T: A Comparison of MOLLI and ShMOLLI across Healthy Volunteers and Various Cardiovascular Pathologies.. Radiology. https://doi.org/10.1148/radiol.252886